Question: 102
In setting up a CO analyzer, a pulmonary function technologist notices that the analyzer reads -0.03 while sampling air. The technologist should
1. Accept the reading because it is within -¦ 3%.
2. Adjust the reading to +0.03.
3. Adjust the reading to 0.00.
4. Reverse the sample flow.
Answer: C
Question: 103
A patient's vital capacity is slightly reduced, the FEWFVC is normal, and the uncorrected DLco is increased. Which of the following is the most likely diagnosis?
1. diffuse pulmonary fibrosis
2. diaphragmatic hemiparesis
3. kyphoscoliosis
4. polycythemia vera
Answer: D
Question: 104
The following results are obtained from an adult male:
The corrected DLco value -
1. is unchanged.
2. is higher.
3. is lower.
4. cannot be calculated.
Answer: A
Question: 105
To check the reliability of a pulse oximeter reading, a pulmonary function technologist should
1. Calculate the SaO2 from pH and PaO2
2. Perform hemoximetry
3. Measure the hematocrit
4. Have the patient hyperventilate
Answer: B
Question: 106
A 54-year-old male who smokes presents to the pulmonary laboratory for chronic cough and dyspnea on exertion. PFT and blood gas results show the following:
Which of the following should the pulmonary function technologist recommend?
1. DLco measurement
2. Oxygen therapy with exercise
3. Trial of varenicline (Chantix)
4. Lung volume measurement
Answer: A
Question: 107
Which of the following is a suitable policy for following Standard Precautions in a pulmonary function laboratory?
1. Eye protection is required when obtaining ABGs from patients with hepatitis.
2. Reusable mouthpieces should be disposed when a patient has a history of tuberculosis.
3. Gloves are optional when obtaining arterial blood samples using a kit
4. Reusable mouthpieces should be disinfected between each patient.
Answer: B
Question: 108
While assessing a patient's expired gases at rest prior to exercise, a pulmonary function technologist calculates the RER as 0.6. Which of the following is the most likely explanation?
1. B. gas analyzer is malfunctioning
2. A gas analyzer is malfunctioning
3. The expired gas is contaminated with air
4. The patient is hyperventilating
Answer: B
Question: 109
Which of the following is an appropriate reason to perform a multiple-breath nitrogen washout test?
1. Measure anatomical dead space.
2. Differentiate obstruction from restriction.
3. Detect early small airway disease.
4. Measure oxygen consumption.
Answer: C
Question: 110
During daily quality control procedures on an infrared CO2 analyzer, a pulmonary function technologist is unable to adjust the gain to the calibration gas concentration. Which of the following is the most likely explanation?
1. Water droplets in the sample cell
2. Saturation of the soda lime
3. Presence of high levels of oxygen
4. Increased gas sampling rate
Answer: A
Question: 111
A patient who is about to begin pulmonary function testing is visibly upset and complains to a pulmonary function technologist that she felt a receptionist was rude to her. Which of the following should the technologist do?
1. Try to get the patient to calm down by telling her that the receptionist is probably just having a bad day.
2. Give the patient time to calm down and ask the laboratory manager to become involved.
3. Ignore the complaint because it is not going to affect the testing about to begin.
4. Accompany the patient back to the reception area and try to determine who was at fault.
Answer: B

User: Nastashi*****

Passing the rpft exam with Killexams.com was a significant achievement, bringing me a sense of pride and recognition. Their high-quality materials provided the support I needed to succeed and make my mark.
User: Zoya*****

Concise answers helped me score high on the RPFT exam despite my busy schedule. Their prepared questions were a perfect study aid, and I passed with top marks.
User: Alice*****

I am grateful to Killexams.com for their full-length mock tests of the rpft exam. I passed on my first attempt with a score of 79%, thanks to their comprehensive guide. Their team is wonderful, and I encourage them to keep up the good work by updating their materials.
User: Verochka*****

As Aggarwal from Clever Corp, I was concerned about the REGISTERED PULMONARY FUNCTION TECHNOLOGIST exam’s complex case studies, but killexams.com’s testprep questions and answers provided clear explanations and solved cases, resulting in a 73% score. Their support was instrumental, and I am happy to credit them for my success.
User: Abdallah*****

Valid and reliable registered pulmonary function technologist testprep practice tests gave me the confidence to excel in my exam. Self-testing before the test ensured I was well-prepared, and I am grateful for their support in achieving a strong score.

Features of iPass4sure RPFT Exam

  • Files: PDF / Test Engine
  • Premium Access
  • Online Test Engine
  • Instant download Access
  • Comprehensive Q&A
  • Success Rate
  • Real Questions
  • Updated Regularly
  • Portable Files
  • Unlimited Download
  • 100% Secured
  • Confidentiality: 100%
  • Success Guarantee: 100%
  • Any Hidden Cost: $0.00
  • Auto Recharge: No
  • Updates Intimation: by Email
  • Technical Support: Free
  • PDF Compatibility: Windows, Android, iOS, Linux
  • Test Engine Compatibility: Mac / Windows / Android / iOS / Linux

Premium PDF with 111 Q&A

Get Full Version

All Medical Exams

Medical Exams

Certification and Entry Test Exams

Complete exam list