Question: 72


A customer needs to aggregate uplink ports from two Virtual Connect interconnects to increase bandwidth and availability of the networks configured for HPE Synergy platform.

Which steps must the integrator perform in the configuration to meet the customer’s needs?

  1. Connect Satellite modules using Ports L1 and L4

  2. Connect Ports Q7 and Q8 on the Master interconnect Modules (ICM)

  3. Install Redundant Frame Link Modules and a second management ring

  4. Enable Intelligent Resilient Fabric (IRF) on the Virtual Connect Modules


Answer: A


Question: 73


Which component of the HPE Synergy solution should you use to set the firmware/driver baseline and the installation method for Synergy Compute nodes?

  1. Composer

  2. Smart Update

  3. Image Streamer

  4. Global Dashboard


Answer: B


Reference: https://support.hpe.com/hpsc/doc/public/display?docId=c05212310

Question: 74


Which storage solution can be used for volume provisioning using HPE Composer?

  1. MSA 2040

  2. HPE StoreEasy 1560

  3. HPE 3PAR StoreServ

  4. HPE XP7 Storage


Answer: C


Reference: https://www.karma-group.ru/upload/iblock/30b/hpe_synergy_composer.pdf

Question: 75


An integrator prepares deployment documents with the list of all the hardware and software components. The integrator also needs a list of all infrastructure services deployed, with the functionality described.

Which services are provided by the vCenter Server component and should be placed in the report? (Choose two.)

  1. Auto Deploy

  2. Single Sign-On

  3. Update Manager

  4. Lookup Service

  5. Certificate Authority

Answer: CD


Question: 76


A customer needs to evaluate Image Streamer as Proof-of-Concept (PoC) in a test and development tab environment. At a minimum, what does a Synergy integrator need in order to support this requirement?

  1. a three-frame environment with redundant composer and Image Streamer appliances

  2. a single frame with single composer and Image Streamer appliances

  3. a two-frame environment with single composer and Image Streamer appliances

  4. a single frame with redundant Image Streamer appliances


Answer: B


Question: 77


An integrator is installing three Synergy frames in different locations for a customer. As part of the installation, the customer requests a single monitoring dashboard that shows the current hardware status, warranty status, and open support cases of all three frames.

Which configuration steps must the integrator perform to provide the customer with this functionality?

  1. Enable Remote Support and Insight Online Integration in the Composer UI

  2. Install Insight Remote Support Advanced, and integrate it with HPE Global Dashboard

  3. Configure OneView with iLO Amplifier pack

  4. Activate iLO Federation on all installed compute nodes


Answer: C


Question: 78


What are valid uses for an IPv4 address pool when configuring an HPE Synergy solution? (Choose two.)

  1. assignment of IP addresses for NICs in an operating system

  2. assignment of IP addresses for Composer appliances

  3. assignment of IP addresses for PXE booting to a deployment server

  4. assignment of IP addresses for interconnect modules

  5. assignment of IP addresses for iLOs


Answer: DE


Reference: https://techlibrary.hpe.com/docs/synergy/shared/setup_overview/index.html

Question: 79


Which policy can an integrator apply when creating a datastore using HPE OneView for vCenter Server?

  1. Data at Rest encryption policy

  2. Round Robin load balancing policy

  3. Recovery Manager Central policy

  4. virtual machine Restart policy


Answer: C

Question: 80


Refer to the exhibit.

How should an integrator pair interconnect bays to set up redundant fabrics in an HPE Synergy 12000 Frame?

  1. Interconnect bays 1 and 2; bays 3 and 4; bays 5 and 6.

  2. Interconnect bays 1 and 6; bays 2 and 5; bays 3 and 4.

  3. Interconnect bays 1 and 4; bays 2 and 5; bays 3 and 6.

  4. Interconnect bays 1 and 3; bays 2 and 4; bays 5 and 6.


Answer: C


Reference: https://h20195.www2.hpe.com/v2/GetPDF.aspx/c04815113.pdf

Question: 81


Refer to the exhibit.

An integrator needs to add an FCoE connection to the server profile, but the FCoE connection type is not available.

What is the likely cause of this issue?

  1. FCoE capable interconnect modules are not installed in the Synergy frame

  2. Defined FCoE network is not associated with a SAN or does not have VLAN Id defined

  3. A FCoE connection is not available, as there is no LIG configured for FCoE connectivity

  4. The FCoE connection has not been added as a Fibre Channel connection within a server profile


Answer: D


Question: 82


In a 3-frame HPE Synergy environment, how should an integrator place the image Streamer modules to allow for redundancy to all of the management connections?

  1. one Image Streamer module in frame 2, and a second Image Streamer Module in frame 3 (2 total)

  2. two Image Streamer modules in frame 2, and two Image Streamer modules in frame 3 (4 total)

  3. one Image Streamer module in each Synergy frame (3 total)

  4. two Image Streamer modules in frame 1 (2 total)


Answer: B


Reference: https://www.karma-group.ru/upload/iblock/2be/synergy_image_streamer.pdf (page 7)

Question: 83


What must an integrator do before an existing cluster can be imported to the HPE Composer?

  1. The vCenter Server must be integrated with the HPE Composer

  2. The cluster must be vSAN enabled

  3. The HPE Composer must have at least two management interfaces to connect to the cluster

  4. The cluster must be enabled for HPE Composer integration


Answer: A


Question: 84


During an initial setup of a Synergy environment, an integrator needs to enable or disable authorized Service access. What will be the outcome when the integrator disables this service?

  1. Authenticated administrators will be unable to make changes to the system

  2. Authorized users will be unable to generate a support dump

  3. Authenticated administrators will be unable to access the system

  4. Authorized support will be unable to diagnose the system


Answer: D


Reference: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c05098314 (62)

Question: 85


FILL BLANK

A customer has the following configuration: Frame 1

  • Bay 1 – HPE Synergy 12Gb SAS Connection Module

  • Bay 2

  • Bay 3 – HPE Virtual Connect SE 40 GB F8 Module

  • Bay 4 – HPE Synergy 12GB SAS Connection Module

  • Bay 5

  • Bay 6 – HPE Synergy 10 Gb Interconnect Link Module Frame 2

  • Bay 1 – HPE Synergy 12Gb SAS Connection Module

  • Bay 2

  • Bay 3 – HPE Synergy 10Gb Interconnect Link Module

  • Bay 4 – HPE Synergy 12Gb SAS Connection Module

  • Bay 5

  • Bay 6 – HPE Virtual Connect SE 40Gb F8 Module

How many more frames can the customer add to their Synergy composable fabric? (Note: Enter your answer in the answer field below.)

A. See explanation below.


Answer: A


Frame 1 – Bay 2 – HPE Virtual Connect SE 100Gb F32 Module for Synergy (867796-B21)

Frame 1 – Bay 5 – HPE Virtual Connect SE 16Gb Fibre Channel Module for Synergy (779227-B21)

Frame 2 – Bay 2 – Brocade 16Gb/24 Power Pack+ Fibre Channel SAN Switch Module for HPE Synergy (K2Q86A) Frame 2 – Bay 5 – HPE Synergy 4820C 10/20/25Gb Converged Network Adapter (876449-B21)


User: Pushkin*****

With only 12 days left to prepare for the HPE0-S58 exam, I felt overwhelmed and in need of a quick and effective guide. Fortunately, I found Killexams and their Questions and Answers. Their concise answers were easy to complete within 15 days, and I was able to score 88% in the actual HPE0-S58 exam. The practice tests they supplied were also very helpful, with 90% of the questions appearing on the actual exam. I owe my success to Killexams.
User: Mack*****

The Questions and Answers from Killexams.com were perfect for my needs. I scored 89% on the HPE0-S58 exam, and I am immensely grateful for their expertise. The practice test was comprehensive and incredibly beneficial.
User: Vadim*****

Overall, Killexams.com was an incredible resource for me to prepare for the hpe0-s58 exam. Although all the questions on the exam were not identical to what was provided by Killexams.com, over 70% were similar, which was quite impressive. While I managed to pass the exam, I still believe that one should not rely solely on this platform and should use their own intellect and study materials to achieve greater success.
User: Gabriel*****

Killexams.com delivered on every promise for the hpe0-s58 exam. Their real questions, flawless simulator, and excellent support led me to a top score—something I once thought unattainable.
User: Florencia*****

Thanks to Killexams.com, I was confident I would score 93% on the hpe0-s58 exam—and I did. Their guide mirrored the actual test, making my last-minute preparation effective.

Features of iPass4sure HPE0-S58 Exam

  • Files: PDF / Test Engine
  • Premium Access
  • Online Test Engine
  • Instant download Access
  • Comprehensive Q&A
  • Success Rate
  • Real Questions
  • Updated Regularly
  • Portable Files
  • Unlimited Download
  • 100% Secured
  • Confidentiality: 100%
  • Success Guarantee: 100%
  • Any Hidden Cost: $0.00
  • Auto Recharge: No
  • Updates Intimation: by Email
  • Technical Support: Free
  • PDF Compatibility: Windows, Android, iOS, Linux
  • Test Engine Compatibility: Mac / Windows / Android / iOS / Linux

Premium PDF with 85 Q&A

Get Full Version

All HP Exams

HP Exams

Certification and Entry Test Exams

Complete exam list