Question: 14
A company has a four-node Microsoft Windows cluster that runs Microsoft SQL Server databases. Each server boots from its own Boot from SAN volume on the Storage Center. All servers need access to the database volumes. In addition, a server cluster objects has been created with the four servers assigned to it in Dell Storage Manager.
How should the volumes be mapped to these servers using the server cluster?
Map the boot volume of each server individually Map all database volumes to the clusterâs Leader node
Map the boot volume of each server individually Map all database volumes to the server cluster
Map all boot volumes to the server cluster
Map all database volumes to each server individually
Map all boot volumes to the server cluster Map all database volumes to the server cluster
Answer: C Question: 15
You need to install a dual controller Storage Center with an SC200 enclosure and an SC280 enclosure. Which exhibit represents the correct back-end cabling?
A)
B)
C)
Option A
Option B
Option C
Option D
Answer: A Question: 16
You are adding a 4-port FC card into the SC9000 storage array. Slots 4 C 6 are occupied and Slot 4 contains a half- height card.
Which actions should occur to free up the full height slot and add the FC card? A)
B)
C)
D)
Option A
Option B
Option C
Option D
Answer: C Question: 17
A company has multiple Storage Centers at their primary site and a disaster recovery system at their remote site. Because there company has an important volume that request high availability protection, an outage on one system at the primary location must not cause data to be inaccessible. In addition, disaster recovery protection is required to protect data even if the primary site goes down.
Which recommended technology meets these requirements?
Live Volume Managed Replication
Fluid Data Architecture
Synchronous Replication
Asynchronous Replication
Answer: A Question: 18
During the deployment of an SC Series storage array, the redundancy of a tier may be restricted dual redundancy. What is the cause for this behavior?
Depending on the drive firmware level and drive sire, Dell Storage Manager will enforce dual redundancy
Depending on the drive speed, drive sire, and SCOS version, dual redundancy may be enforced
Depending on the drive manufacturer and SCOS version, Del Storage Manager will enlace dual redundancy
Depending on the number of spares configured on the system and SCOS version, dual redundancy may be enforced
Answer: A Question: 19
You need to physically install an I/O card into an SC9000 storage array. What must be considered when installing the I/O card?
I/O card BIOS and IPC connection
ESD and I/O slot priority
I/O slot priority and I/O card BIOS
IPC connection and ESD
Answer: A Question: 20
A storage administration needs to enable regular Data Progression to move data between storage tiers. While navigating through the Volume Create wizard, which storage profile should be selected?
Low Priority
Medium Priority
High Priority
Recommended
Answer: C Question: 21
You map a volume to a Microsoft Windows 2012 R2 server and scan for disks within the Windows Disk Management Console. You are able to see multiple Instances of the mapped volume. In addition, the operating system was recently installed on the server that is experiencing the issue. No additional features have been added.
Which action should occur within Windows to correct the issue?
Add the Storage Center specific harware ID within Windows MPIO Select the disk object with the lowest number and delete the rest Verify the iSCSI Initiator service runs on the server
Add the Storage Center specific harware ID within Windows MPIO Add the âMultipath I/Oâ server feature
Reboot the server after making the correct configuration changes
Select the disk object with the lowest disk number and delete the rest Add the âMultipath I/Oâ server feature
Reboot the server after making the correct configuration changes Verify the iSCSI Initiator service runs on the server
Answer: B Question: 22
You notice that servers connecting through iSCSI are not performing as expected. After reviewing the graphics, you identify high latency due to an excessive number of retransmissions.
What is causing the performance issue?
System uses the standard MTU size
Switch firmware is out of date
VLAN ID value is set on the properties of the server NIC
Flow Control is disabled
Answer: C
Question: 23
A deployment engineer is installing a dual-controller Storage Center with four FC ports in each controller. This system need to use Legacy Port mode because the AIX version used requires it.
Which two configurations are required to set up the fault domains?
Only two fault domains; one for the primary ports and one for the reserved ports Primary and reserved ports in the fault domain need to reside on the same controller
Only two fault domains; one zone for all ports in each fabric
Primary and reserved ports in the fault domain need to reside on the different controllers
A separate fault domain for each set of primary and reserved ports
Primary and reserved ports in the fault domain need to reside on different controllers
A separate fault domain for each set of primary and reserved ports
Primary and reserved ports in the fault domain need to reside on the same controller
Answer: C Question: 24
You want to perform an SCOS ISO update.
However, you need to determine the BMC IP address first. What is one way to determine the BMC IP address?
Select the âHardwareâ tab from the Data Collector to display the BMC IP address for each controller
Select the âStorage Centersâ tab from the Data Collector to display the BMC IP address for each controller
In the Dell Storage Manager Client, highlight the controller under the âHardwareâ tab and select Edit Settings
Perform a trace route from the controller CLI to the virtual IP address
Answer: B Question: 25
A company experienced complete storage outages on some of their servers. The outages occurred when network maintenance was performed within their iSCSI network.
Which configuration areas should be investigated to prevent future outage?
Ensure Delayed Acknowledgment has been disabled on the iSCSI adapters. Ensure all server iSCSI adapter are able to communicate with the storage.
Ensure the servers are set up for multipathing with Round Robin.
Ensure Deplayed Acknowledgment has been disabled on the iSCSI dapters.
Ensure the iSCSI adapters are set up for Jumbo Frames.
Ensure all server iSCSI adapters are able to communicate with the storage.
Ensure the servers are set up for multipagthing with Round Robin Ensure all server iSCSI adapters are able to communicate with the storage.
Answer: C
User: Ibrahim*****![]() ![]() ![]() ![]() ![]() Questions were nearly identical to the dee-1721 exam, allowing me to finish in just 30 minutes. Their materials are a must for anyone serious about passing. |
User: Stephanie*****![]() ![]() ![]() ![]() ![]() I achieved an 88% score on my DEE-1721 exam, thanks to a friend’s recommendation to use killexams.com’s questions and answers. The testprep materials were of outstanding quality, simplifying my preparation. Registering for the exam was straightforward, but the real challenge was balancing my part-time job with study. Choosing to study independently with killexams.com’s resources allowed me to continue working while preparing effectively. |
User: Alec*****![]() ![]() ![]() ![]() ![]() As a regular user, I can confirm killexams.com’s dee-1721 testprep materials are reliable, with over 90% correct answers and frequent updates. Their consistent support has been invaluable, and I am hopeful for a discount on my next package, grateful for their dependable resources. |
User: Norbert Clown*****![]() ![]() ![]() ![]() ![]() Exceptional testprep materials helped me score a remarkable 92% on my DEE-1721 certification exam. The technical concepts and language were initially challenging, but their easy-to-understand solutions made preparation manageable. This platform is an outstanding resource for professional certification exams. |
User: Tiauna*****![]() ![]() ![]() ![]() ![]() I highly recommend killexams.com to anyone preparing for the dee-1721 exam. Their practice tests not only reinforced key concepts but also provided a clear understanding of the exam’s question patterns. The materials were comprehensive and well-structured, making preparation efficient and effective. Killexams.com’s exceptional service gave me the confidence to excel, and I am grateful for their support. |
Features of iPass4sure DEE-1721 Exam
- Files: PDF / Test Engine
- Premium Access
- Online Test Engine
- Instant download Access
- Comprehensive Q&A
- Success Rate
- Real Questions
- Updated Regularly
- Portable Files
- Unlimited Download
- 100% Secured
- Confidentiality: 100%
- Success Guarantee: 100%
- Any Hidden Cost: $0.00
- Auto Recharge: No
- Updates Intimation: by Email
- Technical Support: Free
- PDF Compatibility: Windows, Android, iOS, Linux
- Test Engine Compatibility: Mac / Windows / Android / iOS / Linux
Premium PDF with 106 Q&A
Get Full VersionAll DELL-EMC Exams
DELL-EMC ExamsCertification and Entry Test Exams
Complete exam list